Release Notes for Version 2.00.08
This version fixes the following problems and bugs of version
2.00:
- DXF-Converter dxfconv (converting DXF to RADIANCE
directly): POLYLINE entities were shifted to wrong location during
conversion.
- SUPERLITE: Saving of input files to disks from the user interface
was wrong in case of models not containing enclosure surfaces.
This lead to a crash when the graphical input control or the simulation
was started.
- SUPERLITE graphics: Selecting a simulation hour other than
the first in the simulation loop was not possible. Fixed now.
- SUPERLITE graphics: Graphics output was not possible for clear
sky models. Fixed now.
- SUPERLINK: Read error for plot files (sky model 2 - clear
sky with sun) fixed.
- SUPERLITE: Data for overhangs was not written correctly when
input file was saved to disk in case of multiple windows. Bug
fixed.
- SUPERLITE: For comprehensive input mode, overhang reflectance
and transmittance other than 0% was not possible to enter. Bug
fixed.
- SUPERLITE: For comprehensive input mode, display of check
box window has overhang in window dialog was wrong. Bug
fixed.
- PLINK/SUPERLITE: Location of overhangs in SUPERLITE comprehensive
input mode was wrong in case of windows with height/width >
1. Reason: PLINK does rearrangement of polygon vertices in order
to fix the local coordinate system of each surface to the longest
edge. Bug fixed: Rearrangement is supressed for all window
element types. Note that rearrangement is still performed
for all other element types.
- SUPERLITE graphics output: Data readin error for sky model
2 (clear sky with sun) in case of models with multiple clear windows
fixed.
- SUPERLITE: Output plot was not possible for weather model
<> 2 (no time loop). Bug fixed.
- SUPERLITE: Changes in output graphics option dialog: if the
weather model <> 2 (no time loop), then the month/hour entries
are unavailable. If a time loop is used, then the month/hour entries
are initialized to the first month/hour in the loop automatically.
- SUPERLITE: Program crashed when an input file in wrong format
(e.g. ADELINE 1.0 format) was read in. Bug fixed.
- SUPERLITE output graphics: In some cases the window projection
was not displayed correctly. Bug fixed.
- SUPERLITE output graphics: Sun patch was not shown for clear
sky with sun conditions. Bug fixed.
- SUPERLITE output graphics: External surfaces (enclosure_a/b)
were not taken into account during sun patch calculation. Bug
fixed.
- SUPERLITE: Reading of window type identifiers was wrong comprehensive
mode, i.e. all windows were displayed as clear windows.
Bug fixed.
- SUPERLITE: Writing of enclosure obstruction data from user
interface to file was wrong in case of enclosures with more than
one surface. Bug fixed.
- SUPERLINK: Due to conversion error for exterior horizontal
illuminance, SUPERLINK reported no energy savings at all for some
model (e.g. the tutorial model). Bug fixed.
- SUPERLINK: Additional dialog box for user confirmation of
new SUPERLITE runs to prevent unwanted overwriting of files.
- SUPERLITE: In version 2.00.06 a bug has been introduced which
crashed the user interface program when the output plot for a
SUPERLITE file is started (message appears onscreen telling the
user that a file with a weird name is not found). Bug fixed.
- SUPERLITE: In the output plot program a bug has been fixed
which suppressed the plot output in case of more than 200 nodes
on the selected work surface.
- SUPERLITE: A bug in the electric lighting component has been
fixed which caused strange displays of models in the input plot.
- RADLINK: A bug was fixed so that the worksurface data will
be read and rewritten when *.rif file are handled.
- SUPERLINK/RADLINK: The holiday-file dialog has been altered.
Holiday files can be edited from the dialog now. Please be aware
that the saved holiday file only is the handeled program parameter,
so save the file after changing the holiday list contens.
New Patch Versions
are available via WWW from the ADELINE WWW-Server at IBP.
Known Problems and Unfixed Bugs
- SUPERLITE Graphics: Plot is only possible if not more than
20 nodes are used in each axis direction on the work surfaces.
Work around: Use coarser grid (see Edit|General... dialog)
- SUPERLITE: When the accuracy parameters (node distribution)
for comprehensive models are changed within the user interface
program (via Edit|General...), the node distribution is
not changed for the surfaces. Will be fixed a.s.a.p.
Work-around: After the parameters have been changed, save them
to a parameter definition file using File|Save Parameters as...
. Re-import the SCRIBE model again using this parameter file.
Last changed: September 26, 1996 jst@ibp.fhg.de